1640	Connectors in models are not updated	jez	jez	"1. Create an own connector, draw a circle in icon view and a rectangle in diagram view
2. Create a model - ""beta""
3. drag this connector to your model beta
4. Create model ""gejma""
5. add beta component to gejma
6. Modify ""beta"" - i.e. add another connector
7. in ""gejma"" the block stays the same, even after save.

Only restart of OME helps - which is not simple, since you cannot use packages. You have to load all three models separately."	defect	assigned	high	Future					jez Adeel Asghar