﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1965	TriggeredSampler model doesn't switch properly	Peter Junglas	Willi Braun	"In the model TestTriggeredSampler1 a TriggeredSampler is triggered when the Clock reaches the (integer) value 2, i.e. at time 1.5. But its output doesn't change.

The model TestTriggeredSampler2 uses an integer step instead of the clock - this works.

I'm using MSL 3.2.1 and OpenModelica1.9.0 Beta2 (r14139)
"	defect	closed	high	1.9.0	Backend	trunk	fixed		