1985	FMI import  fail to use input varibles	anonymous	Adeel Asghar	"Input variables 
(for example 
  Modelica.Blocks.Interfaces.RealInput pr_meas annotation(Placement(transformation(extent = {{-120,60},{-100,80}})));
  Modelica.Blocks.Interfaces.RealInput ps_meas annotation(Placement(transformation(extent = {{-120,35},{-100,55}})));
  Modelica.Blocks.Interfaces.RealInput pf_meas annotation(Placement(transformation(extent = {{-120,-15},{-100,5}})));
)

are present in the initial algorithm: 
(
initial algorithm
 ..
  flowParamsStart:=fmiFunctions.fmiSetReal(fmi, {2.0,3.0,8.0,9.0}, {pr_meas,ps_meas,pp_meas,pf_meas});
 )

but not in the equation or algorithm sections. After initialization the input variables have no effect. If I manually add similar row, as in the initial algorith, for example in algorithm block, simulation seems to work as expected.



"	defect	closed	high	1.9.0	FMI	trunk	fixed		