﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
3307	translation fails because of (lack of) potential and flow variables where all signals are inputs or outputs	Michael Wetter	somebody	"I want to export a fluid flow component (similar to Modelica.Fluid) as an FMU. The translation fails because the number of potential variables is not equal to the number of flow variables. The model has, however, only input or output signals, and no flow variable should be used in this case.

I created the following test case that reproduces the error. It does not use any Fluid or Media, but rather only has input or output signals. In my view, this model is well-posed:
{{{
package MIMO

    connector FluidProperties ""Type definition for fluid properties""
      // No input or output is declared here, as the whole connector
      // can be all input or all output variables.
      Modelica.SIunits.SpecificEnthalpy h ""Specific thermodynamic enthalpy"";
      Real X_w ""Water vapor mass fractions per kg total air"";
    end FluidProperties;

    connector inlet
      input Modelica.SIunits.MassFlowRate m_flow;
      input Modelica.SIunits.AbsolutePressure p;
      input FluidProperties proFor;
      output FluidProperties proBac;
    end inlet;

    connector outlet
      output Modelica.SIunits.MassFlowRate m_flow;
      output Modelica.SIunits.AbsolutePressure p;
      input FluidProperties proBac;
      output FluidProperties proFor;
    end outlet;

block MIMO ""Test model""

  inlet inlet1 annotation (Placement(transformation(extent={{-110,-10},{-90,10}}),
        iconTransformation(extent={{-110,-10},{-90,10}})));
  outlet outlet1 annotation (Placement(transformation(extent={{90,-10},{110,10}}),
        iconTransformation(extent={{90,-10},{110,10}})));
equation 

  connect(inlet1, outlet1)
    annotation (Line(points={{-100,0},{100,0},{100,0}}, color={0,0,0}));
  annotation (uses(Modelica(version=""3.2.1"")), Diagram(coordinateSystem(
          preserveAspectRatio=false, extent={{-100,-100},{100,100}})));
end MIMO;
  annotation (uses(Modelica(version=""3.2.1"")));
end MIMO;
}}}

The detailed message is:
{{{
[1] 14:50:53 Translation Warning
[MIMO: 12:5-17:14]: Connector .MIMO.inlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).

[2] 14:50:53 Translation Warning
[MIMO: 4:5-10:24]: Connector .MIMO.FluidProperties is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).

[3] 14:50:53 Translation Warning
[MIMO: 19:5-24:15]: Connector .MIMO.outlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).

[4] 14:50:53 Symbolic Error
[: 0:0-0:0]: Too few equations, under-determined system. The model has 6 equation(s) and 10 variable(s).

[5] 14:50:53 Translation Error
[: 0:0-0:0]: Internal error pre-optimization module clockPartitioning failed.
}}}

A slightly more complex model is Buildings/Fluid/FMI/Examples/FMUs/TwoPortPassThrough from
{{{
git clone git@github.com:lbl-srg/modelica-buildings.git
cd modelica-buildings
git checkout issue313_fmi
}}}

"	defect	new	high	Future	Backend	trunk			