﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
3500	Incorrect numerical output not detected	dma@…	Willi Braun	"When the stop time of the attached simulation is increased from 2 to 100, a clearly incorrect result is produced but no error indication is given. When the number of output intervals is increased from 500 to 5000 the correct result is given.

It seems that the solver (dassl) uses the stop time and number of intervals for a first guess at step size. With num. of intervals at 500 the step size is much too large, but its error estimator does not properly catch the error."	defect	closed	critical	1.9.4	Run-time		fixed	solver error, state selection	