﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
3865	OMEdit fails to import a 2.0 FMU that contains both ME and CS	Christian.Bertsch@…	Martin Sjölund	"The Error occurs with: OMEdit v1.9.5-dev-20-g6cc344e; Connected to OpenModelica v1.9.6 and the attached FMU exported from Dymola. According to the FMI specifictaion, it is allowed, that an FMU containes both ME and CS implementations.

There is an additional error regarding derivatives attributes, while the FMI compliance Checker reports not errors or warnings.
***

Error Messages:

[1] 19:47:51 Skripting Fehler
module = The derivative attribute may only appear on continuous-time Real variables., log level = ERROR: FMI2XML

[2] 19:47:51 Skripting Fehler
The FMU version is 2.0 and FMU type is ModelExchange and CoSimulation. Unsupported FMU type. Only FMI 2.0 ModelExchange is supported.
"	defect	closed	high	1.13.0	FMI	v1.9.4-v1.9.x	fixed	FMI, CS, ME	