﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
4031	Issues with OMEdit and components from the PowerSystems library	Francesco Casella	Adeel Asghar	"Open `PowerSystems.Examples.Spot.Introduction.Frequency` in OMEdit and see:
1. The Windows version of OMEdit (v1.10.0-dev-159-g4de9151) will hide the `+` and `-` navigation elements in the tree view of the Libraries pane on mouseover (just not nice, but see below). The Linux version (v1.10.0-dev.134+gb85235d) does it right.
1. OMEdit shows all conditional signal inputs of voltage1 and voltage2 even if they are disabled (see #2081)
1. double click on `voltage1` to open the parameter dialog -- the Windows version of OMEdit  will destroy the diagram layout -- the Linux version keeps the position of the icon in the diagram
1. OMEdit shows the Scripting Error ""error parsing unit VA""
- The voltage veff is in p.u., which is represented with ""V/V"", relative to V_nom, in the PowerSystems library. OMEdit proposes the alternative units ""rad"" and ""sr""!?
1. OMEdit does not propose alternative units for `V_nom`, just ""V"" -- ""kV"" would be nice.
1. The angle alpha0 is shown with the SI unit ""rad"". OMEdit proposes to alternatively use ""sr"". Why doesn't OMEdit use or even propose the displayUnit ""deg""?
1. OMEdit proposes for the frequency `f` the alternative unit ""Bq"". `f` is bound to the parameter `system.f`. What is the meaning of changing the display unit of a variable name?

Once you got around all these things, you finally find out that `fType_par` is always disabled, independent of the actual value of `fType_sys`. It appears that OMEdit generally lacks the evaluation of parameters when rendering graphics or parameter dialogs, see #2661 and #4008.

Originally reported by @rfranke as a comment in #4008.
"	defect	new	blocker	2.0.0	OMEdit				Rüdiger Franke Adrian Pop