﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
4603	Provide support for start-value selection according to the Modelica Specification	Francesco Casella	Karim Adbdelhak	"The Modelica Specification, section 8.6.2, provides a non-normative procedure to select start values in case of alias variables. This requires the front-end to produce a ''confidence number'' based on the level at which the start value is set or modified.

I understand from @ptauber that this number is not available in the back-end, so the selection is based on the ''cref depth'' instead.

It would be nice if this information was computed by the new front end, so it could be used by the back-end."	defect	assigned	high		New Instantiation				Lennart Ochel Andreas Heuermann Per Östlund