﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
4725	Issues with equation count in NF due to incorrect conditional component handling	Francesco Casella	Per Östlund	"Please check {{{Modelica.Electrical.Machines.Examples.DCMachines.DCEE_Start}}}. With the old front end, 246 equations and 246 variables are reported. With the new front-end, 261 equations and 258 variables are reported.

By comparing the flattened equations with the old and new FE, it is apparent that the new FE instantiates variables such as {{{dcee.thermalPort.heatPortCore.T}}}, which are not instantiated by the old FE, as well as the corresponding equations. This is most probably related to conditional components not being instantiated correctly."	defect	closed	high	2.0.0	New Instantiation		fixed		