4817	DAES generated by the NF do not pass the initialization phase	Francesco Casella	Lennart Ochel	"Please check [https://libraries.openmodelica.org/branches/newInst/Modelica_3.2.2/files/Modelica_3.2.2_Modelica.Electrical.Digital.Examples.DFFREG.err Modelica.Electrical.Digital.Examples.DFFREG]. When the NF is used to flatten the model, the following error is reported after matching and sorting:
{{{
Error: No system for the symbolic initialization was generated
}}}

This issue affects many other models in the MSL."	defect	closed	high	2.0.0	New Instantiation		fixed		Per Östlund