﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
4993	Parameter-dependent conditional equations are not handled by the NF	Francesco Casella	Per Östlund	"Consider the following test case
{{{
model Test 
  Real x[2];
  parameter Boolean p[2] = {false, true};
equation
  x[1] = 1;
  for i in 1:2 loop
    if p[i] then
      x[i] = 2;
    end if;
  end for;
end Test;
}}}
Section 8.3.4 of the specification states

  If-equations in equation sections which do not have exclusively parameter expressions as switching conditions shall have the same number of equations in each branch

so this model is valid, since {{{p[i]}}} is a parameter expression.

The old front end flattens this model to 
{{{
class Test2
  Real x[1];
  Real x[2];
  parameter Boolean p[1] = false;
  parameter Boolean p[2] = true;
equation
  x[1] = 1.0;
  x[2] = 2.0;
end Test2;
}}}

which is correct, and then simulates it correctly.

The NF instead produces this flat code
{{{
class Test
  Real x[1];
  Real x[2];
  parameter Boolean p[1] = false;
  parameter Boolean p[2] = true;
equation
  x[1] = 1.0;
  if p[1] then
    x[1] = 2.0;
  end if;
  if p[2] then
    x[2] = 2.0;
  end if;
end Test;
}}}
then, when trying to simulate it, produces the following error:
{{{
[1] 16:19:58 Symbolic Error
Too few equations, under-determined system. The model has 1 equation(s) and 2 variable(s).
}}}
The problem persists even when setting {{{-d=evaluateAllParameters}}}.

@perost, can you please make sure that these parameter dependent conditions are evaluated properly?

As an interim measure, getting them right with {{{-d=evaluateAllParameters}}} would already be good.
"	defect	closed	high	2.0.0	New Instantiation		fixed		danieljose.penagos@…