﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
5176	The CI verification results are broken if the reference result file has a wider interval than StopTime	Francesco Casella	Martin Sjölund	"Please check [https://libraries.openmodelica.org/branches/master/Modelica_trunk/files/Modelica_trunk_Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_Steinmetz.diff.loadInertia.phi.html Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_Steinmetz.diff.loadInertia.phi]. The reference trajectory is defined up to time = 1.5. However, the model has StopTime = 1, so OMC only provides data untile time = 1. After that, it considers all variablse constants, which of course causes errors because they don't match the reference data anymore.

Please make sure that the comparison is only carried out on the intersection between the time interval of the reference solution and the time interval of the simulation results."	defect	closed	critical	1.14.0	Testing Framework		fixed		