﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
5357	Evaluating structural parameter (or constant) - Translation Error	KieranF <kieran.fung@…>	somebody	"I recently tried to instantiate the WindFarm.mo located within PowerSystems.Examples.Wind.WindFarm and I received an error message reading:

[1] 10:03:42 Translation Error
[PowerSystems.AC3ph.Machines: 2208:3-2208:47]: Could not evaluate structural parameter (or constant): wt1.generator.c.n_r which gives dimensions of array: L_r. Array dimensions must be known at compile time.

This error was just really confusing to me because no where within the WindFarm.mo was there a use of any model from PowerSystems.AC3ph.Machines library.

All the components used within the WindFarm.mo does indeed have components used within PowerSystems.AC3ph however, that is where it ends. The variable ""n_r"", I believe the rotor speed, is not even used within my model.

If you have any knowledge in this subject, advice or suggestions please feel free to leave a comment! Thanks!"	defect	closed	high	Future	*unknown*		invalid		