﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
5976	Impossible to set parameters with units different from displayUnit (regression!)	massimo ceraolo	Adeel Asghar	"Consider the following model:

{{{
model speed
  Modelica.Mechanics.Rotational.Components.Inertia ICE(J = 0.73, w(displayUnit = ""rpm"", fixed = true, start = 17.48)) annotation(
    Placement(visible = true, transformation(extent = {{-12, -8}, {8, 12}}, rotation = 0)));
equation

annotation(
    Diagram(coordinateSystem(extent = {{-100, -80}, {100, 80}})),
    uses(Modelica(version = ""3.2.3"")));
end speed;
}}}

From the GUI it seems possible to set the initial speed in rad/s, but indeed it is impossible.
Tested with OM v1.16.0-dev-330."	defect	closed	blocker	1.16.0	OMEdit		fixed		