﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
6262	Incorrect start value for an input variable in an FMU exported from OM	jean-philippe.tavella@…	Lennart Ochel	"I try to export FMUs from models built with the recent library PowerSysPro developped by EDF.
For memory, this library is available here: https://bitbucket.org/simulage/powersyspro/wiki/Home
Important note: use the version 1.4 for OM (don't use the last version 1.5 due to discussion in ticket  #6261).

Please refer to the package Examples.ExampleWithFMUs.
I try to export as FMUs for cosimulation from OM the two models MVPartOfMVLVNetwork and LVPartOfMVLVNetwork.
I can do that but the issue is related to the FMU built from LVPartOfMVLVNetwork as the start value for variable v_re (with causality=input) is 0 and it should be 230 (according to the model).

The FMU is correct when exported from Dymola.

Due to this issue, the FMU cannot be loaded in our open-source cosimulator DACCOSIM NG (https://bitbucket.org/simulage/daccosim/wiki/Home).
"	defect	closed	critical	1.17.0	FMI	1.16.0	fixed	FMU	Andreas Heuermann