﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
6287	Handling of parameter records is a nightmare	ahaumer@…	Adrian Pop	"OM 1.16.1 (64 bit) on Windows 10 pro
I'm using parameter records to keep parameters belongig to a drive together. Parameters are structured in sub-records (MachineData and ControllerData), both are instantiated in DriveData. DriveData is instantiated in Examples.
1. You can't access driveData.machineData via the grahical user interface, only textually.
2. You can't redeclare driveData.machineData to another dataset (e.g. Std48V) by drop-down menue in the graphical user interface.
3. Text views shows ""redeclare DC_Drive.DataRecords.MachineDataSets.Std48V machineData"", diagram view shows ""redeclare DC_Drive.DataRecords.MachineDataSets.MachineData machineData"".
4. The compilation fails.
All these things work fine in other modeling and simulation environments. 
It is impossible to use OM for teaching and training!"	defect	closed	high	1.16.2	Interactive Environment	1.16.0	fixed		