1 | | Maybe is not that important for OMEdit to forbid connection of outputs to each other, in case the error is clearly singled out at checking time. |
2 | | So maybe the priority of this ticket could be lowered a notch or two. But if I create a model consisting of two Block.Sources.Constant whose outputs are connected to each other and I check the model the message I get is rather reassuring: |
3 | | |
4 | | {{{ |
5 | | Check of a completed successfully. |
6 | | Class a has 3 equation(s) and 2 variable(s). |
7 | | 3 of these are trivial equation(s). |
8 | | }}} |
9 | | |
10 | | At least when checking the model, direct connection of two outputs should be clearly indicated as an error. Therefore I leave the prioirty of this ticket unchanged. |
| 1 | Maybe is not that important for OMEdit to forbid connection of outputs to each other, since it results in an over-determined system, as is clearly stated when checking and running the model. |
| 2 | Thus I will reduce the priority of this ticket. |