Opened 7 years ago
Last modified 4 years ago
#5404 assigned defect
postOpt modules dont work with synchronous equations — at Initial Version
| Reported by: | Maksimov Doe | Owned by: | Lennart Ochel |
|---|---|---|---|
| Priority: | high | Milestone: | |
| Component: | Backend | Version: | |
| Keywords: | Cc: |
Description
This simple synchronous equation system
model Example1 Real x, y; equation when Clock(0.1) then x + y = 0; x - y = 0; end when; end Example1;
produce an under-determined system
########################################
dumpindxdae
########################################
clocked partition(1)
======================================== Variables (2)
========================================
1: y:VARIABLE() type: Real
2: x:VARIABLE() type: Real
Equations (2, 2)
========================================
1/1 (1): -1.0 = 1.0 [dynamic |0|0|0|0|]
2/2 (1): y = -x [dynamic |0|0|0|0|]
Matching
========================================
2 variables and equations
var 1 is solved in eqn 2
var 2 is solved in eqn 1
StrongComponents
========================================
{1:2} Size: 1 Generic Jacobian via directional derivatives
{2:1}
BackendDAEType: simulation
Base partitions (1)
========================================
1: Clock(0.1)[1]
Sub partitions (1)
========================================
1: factor(1/1) shift(0/1) event(false)
It seems like some postOpt modules work with synchronous systems incorrectly.
Note:
See TracTickets