Opened 6 years ago
Last modified 3 years ago
#5404 assigned defect
postOpt modules dont work with synchronous equations — at Initial Version
Reported by: | Maksimov Doe | Owned by: | Lennart Ochel |
---|---|---|---|
Priority: | high | Milestone: | |
Component: | Backend | Version: | |
Keywords: | Cc: |
Description
This simple synchronous equation system
model Example1 Real x, y; equation when Clock(0.1) then x + y = 0; x - y = 0; end when; end Example1;
produce an under-determined system
######################################## dumpindxdae ######################################## clocked partition(1) ======================================== Variables (2) ======================================== 1: y:VARIABLE() type: Real 2: x:VARIABLE() type: Real Equations (2, 2) ======================================== 1/1 (1): -1.0 = 1.0 [dynamic |0|0|0|0|] 2/2 (1): y = -x [dynamic |0|0|0|0|] Matching ======================================== 2 variables and equations var 1 is solved in eqn 2 var 2 is solved in eqn 1 StrongComponents ======================================== {1:2} Size: 1 Generic Jacobian via directional derivatives {2:1} BackendDAEType: simulation Base partitions (1) ======================================== 1: Clock(0.1)[1] Sub partitions (1) ======================================== 1: factor(1/1) shift(0/1) event(false)
It seems like some postOpt modules work with synchronous systems incorrectly.
Note:
See TracTickets