Changes between Version 1 and Version 2 of Ticket #5452, comment 22
- Timestamp:
- 2019-06-20T09:31:54Z (5 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Ticket #5452, comment 22
v1 v2 8 8 Aha, I missed that. 9 9 10 I prepared two updated test models {{{TestIndexReduction3}}} and {{{TestIndexReduction4}}} where I terminated the circuits with a delta-connected resistive load, so that we have the constraint that the three currents are zero.10 I prepared two updated test models {{{TestIndexReduction3}}} and {{{TestIndexReduction4}}} where I terminated the circuits with a delta-connected resistive load, which more accurately reflects the structure of the original MSL model. 11 11 12 12 In the case without rectifier and inverter ({{{TestIndexReduction3}}}), OMC correctly identifies the constraint and performs the right index reduction. In the other case {{{TestIndexReduction4}}} it fails to do so and ends up with an index-2 DAE, that causes the runtime solver to fail.