Opened 15 years ago
Last modified 14 years ago
#1124 closed defect (fixed)
check of Modelica.Thermal.FluidHeatFlow.Examples.PumpAndValve in MSL3.1 fails
Reported by: | Peter Aronsson | Owned by: | Peter Aronsson |
---|---|---|---|
Priority: | high | Milestone: | Red October |
Component: | Version: | ||
Keywords: | Cc: | Peter Aronsson, |
Description
checkModel(Modelica.Thermal.FluidHeatFlow.Examples.PumpAndValve) in MSL3.1 gives:
"Check of Modelica.Thermal.FluidHeatFlow.Examples.PumpAndValve failed
"
"Warning: Parameter dpLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowNominal has no value, and is fixed during initialization (fixed=true)
Error: No constant value for variable dpLaminar in scope Modelica.Thermal.FluidHeatFlow.Components.HeatedPipe.
Warning: Parameter h_g has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter dpLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter dpLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter dpLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowNominal has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter dpNominal has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowNominal has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flowLaminar has no value, and is fixed during initialization (fixed=true)
Warning: Parameter constantAmbientPressure has no value, and is fixed during initialization (fixed=true)
Error: No constant value for variable constantAmbientPressure in scope Modelica.Thermal.FluidHeatFlow.Sources.Ambient.
Warning: Parameter dp0 has no value, and is fixed during initialization (fixed=true)
Warning: Parameter wNominal has no value, and is fixed during initialization (fixed=true)
Warning: Parameter V_flow0 has no value, and is fixed during initialization (fixed=true)
Warning: Parameter wNominal has no value, and is fixed during initialization (fixed=true)
Warning: Parameter y1 has no value, and is fixed during initialization (fixed=true)
Warning: Parameter kv0 has no value, and is fixed during initialization (fixed=true)
Warning: Parameter y1 has no value, and is fixed during initialization (fixed=true)
Warning: Parameter dp0 has no value, and is fixed during initialization (fixed=true)
Warning: Parameter rho0 has no value, and is fixed during initialization (fixed=true)
Warning: Parameter frictionLoss has no value, and is fixed during initialization (fixed=true)
Warning: Parameter m has no value, and is fixed during initialization (fixed=true)
Error: Error occured while flattening model Modelica.Thermal.FluidHeatFlow.Examples.PumpAndValve
"
MathCore TRAC: http://intranet/trac/mathmodelica/ticket/2725
This model works with the recent checkModel fixes, see test case libraries/msl31/Modelica.Thermal.