Opened 11 years ago

Closed 11 years ago

Last modified 10 years ago

#3437 closed defect (fixed)

Failed optimization tests after fix in stream connectors

Reported by: Rüdiger Franke Owned by: Vitalij Ruge
Priority: high Milestone: 1.9.4
Component: Optimization Version: trunk
Keywords: Cc:

Description

The two tests openmodelica/cruntime/optimization/benchmark/{runDrumBoiler,runExReduceDrumBoiler} fail after the fix #3430. The former test might just require an update of the reference file, because temperature.T and T_S changed.

Change History (6)

comment:1 by Adrian Pop, 11 years ago

Component: OMOptim → Optimization
Owner: changed from Hubert Thieriot to Vitalij Ruge

comment:2 by Vitalij Ruge, 11 years ago

Status: new → accepted

comment:3 by Vitalij Ruge, 11 years ago

Resolution: → fixed
Status: accepted → closed

comment:4 by Dietmar Winkler, 11 years ago

Milestone: Future → 1.9.4

Sorting these closed tickets away from "Future". Since they were closed after the last 1.9.3 release, it's very likely that they should have been part of the 1.9.4 release.

comment:5 by Martin Sjölund, 10 years ago

Milestone: 1.9.4 → 1.9.4-1.9.x

Milestone renamed

comment:6 by Martin Sjölund, 10 years ago

Milestone: 1.9.4-1.9.x → 1.9.4

Milestone renamed