#3506 closed defect (fixed)
Buildings flattening broken since f3bb4482
Reported by: | Per Östlund | Owned by: | Per Östlund |
---|---|---|---|
Priority: | high | Milestone: | 1.9.4 |
Component: | Frontend | Version: | |
Keywords: | Cc: |
Description
The following models no longer flatten due to various error:
Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels Buildings.Fluid.Interfaces.Examples.Humidifier_u Buildings.HeatTransfer.Windows.Examples.ElectrochromicWindow Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.CoolingCapacity Buildings.Fluid.Movers.Validation.Power Buildings.Fluid.Movers.Validation.Pump_Nrpm_stratos Buildings.Fluid.Movers.Validation.Pump_stratos Buildings.HeatTransfer.Examples.ConductorSteadyStateTransient Buildings.HeatTransfer.Windows.Examples.FixedShade Buildings.Rooms.BaseClasses.Examples.AirHeatMassBalance Buildings.Rooms.BaseClasses.Examples.InfraredRadiationExchange Buildings.Rooms.BaseClasses.Examples.InfraredRadiationGainDistribution Buildings.Rooms.BaseClasses.Examples.MixedAirHeatMassBalance Buildings.Rooms.BaseClasses.Examples.RadiationTemperature Buildings.Rooms.Constructions.Examples.ExteriorWallWithWindow
Change History (6)
comment:1 by , 9 years ago
Status: | new → accepted |
---|
comment:2 by , 9 years ago
comment:4 by , 9 years ago
Milestone: | Future → 1.9.4 |
---|
Sorting these closed tickets away from "Future". Since they were closed after the last 1.9.3 release, it's very likely that they should have been part of the 1.9.4 release.
Note:
See TracTickets
for help on using tickets.
also Buildings.Electrical.AC.ThreePhasesBalanced.Conversion.ACDCConverter works good with 1.9.4 build 139 but not work good with new versions like build 295 or 300 for example