Opened 6 years ago

Closed 6 years ago

#5024 closed defect (fixed)

Issue with package constant in ThermoSysPro with the NF

Reported by: casella Owned by: perost
Priority: high Milestone: 2.0.0
Component: New Instantiation Version:
Keywords: Cc:

Description

Please check ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7. The following error is reported:

[ThermoSysPro 3.1/WaterSteam/Machines/CentrifugalPump.mo:131:3-135:23:writable]
Notification: From here:
[ThermoSysPro 3.1/WaterSteam/Machines/CentrifugalPump.mo:77:3-77:114:writable] 
Error: Constant centrifugalPump.M is used without having been given a value.

At least 14 models fail because of this issue.

Change History (1)

comment:1 Changed 6 years ago by casella

  • Resolution set to fixed
  • Status changed from new to closed

This issue seems to be fixed. The model now fails because of unimplemented cardinality()

Note: See TracTickets for help on using tickets.