Opened 4 years ago

Last modified 4 years ago

#6319 closed defect

Wrong result in a realistic, PowerGrids-based example — at Initial Version

Reported by: massimo ceraolo Owned by: somebody
Priority: critical Milestone: 1.17.0
Component: *unknown* Version: v1.17.0-dev
Keywords: Cc:

Description

The attached OM.png and Dymola.png show variable IPu as obtained using the models ScTT and ScTT1 from the enclosed Test.mo. Note that this model requires PowerGrids library.

The two results should be identical since ScTT1 just adds some sensors to ScTT.
The Dymola's results are indeed identical.
The OM results are quite different, and the one from ScTT1 is badly wrong:

  • the value during the first 100 ms is totally different (and invalid)
  • the short circuit current (immediately after 100 ms) is too low
  • the current, after an initial reduction after the short circuit occurring at 200ms, rises again: it should continuously reduce

Change History (2)

by massimo ceraolo, 4 years ago

Attachment: Dymola.png added

by massimo ceraolo, 4 years ago

Attachment: OM.png added
Note: See TracTickets for help on using tickets.