Description

[159] 15:53:21 Translation Notification
The given system is mixed-determined. [index = 1]

[160] 15:53:21 Translation Error
Internal error IndexReduction.pantelidesIndexReduction failed! System is structurally singulare and cannot handled because number of unassigned equations is larger than number of states. Use -d=bltdump to get more information.

[161] 15:53:21 Translation Error
No system for the symbolic initialization was generated

Change History (3)

comment:1 by Francesco Casella, 4 years ago

Milestone: NeedsInput1.18.0
Owner: changed from somebody to Francesco Casella
Priority: highnormal
Status: newassigned

@viveksingh, the error message means that the system is one time overdetermined and one time underdetermined. This can happen, e.g., if you connect to components in series who both prescribe the mass flow rate, because the say the same thing twice, while they give no information on the in-between pressure.

Please attach some example that we can run to reproduce the issue, otherwise it's difficult to help further.

comment:2 by Francesco Casella, 3 years ago

Milestone: 1.18.0

Ticket retargeted after milestone closed

comment:3 by Per Östlund, 3 years ago

Resolution: invalid
Status: assignedclosed

Closing due to lack of info.