#5721 closed defect

Redeclare extends on functions not picking up the correct redeclared package/record — at Version 2

Reported by: Mahder Alemseged Gebremedhin Owned by: Per Östlund
Priority: high Milestone: Future
Component: New Instantiation Version:
Keywords: Cc:

Description (last modified by Mahder Alemseged Gebremedhin)

If you flatten this model

model ConstantEffectiveness
 package Medium1 = BuildSysPro.IBPSA.Media.Water;
 package Medium2 = BuildSysPro.IBPSA.Media.Air;

  BuildSysPro.IBPSA.Fluid.Sources.Boundary_pT sou_2(
    redeclare package Medium = Medium2);

  BuildSysPro.IBPSA.Fluid.Sources.Boundary_pT sou_1(
    redeclare package Medium = Medium1);
end ConstantEffectiveness;

You get some functions from the components. e.g.

function ConstantEffectiveness.sou_1.Medium.specificEnthalpy "Return specific enthalpy"
  input ConstantEffectiveness.Medium.ThermodynamicState state "Thermodynamic state record";
  output Real h(quantity = "SpecificEnergy", unit = "J/kg", min = -10000000000.0, max = 10000000000.0, nominal = 1000000.0) "Specific enthalpy";
algorithm
  h := 4184.0 * (state.T - 273.15);
end ConstantEffectiveness.sou_1.Medium.specificEnthalpy;

this function is generated for sou_1 as you can see from the name. However, it seems the record type that is the input to the function is of type ConstantEffectiveness.Medium.ThermodynamicState. This type does not, strictly speaking, exist in the model since the partial Medium from which this type is picked up has been redeclared. It should have been ConstantEffectiveness.sou_1.Medium.specificEnthalpy from sou_1.

I am still not entirely sure what causes this. If you use just one of the components, sou_1 or sou_2 but not both then everything works fine. This is because even though we pick the wrong name/type for the record we at least pick the one with correct elements in it. However, if you use both then the name is used for both and we have issues at codegen time.

Maybe you can find something.

I am trying to duplicate it using a non-library simple model but so far doesn't seem to pinpoint it.

If you need the full model to test with, you can use BuildSysPro.IBPSA.Fluid.HeatExchangers.Validation.ConstantEffectiveness or one of the models from teh coverage where you see errors saying too many or too few arguments to function call ...