#5244 closed defect (fixed)
OMEdit does not show some derivatives
Reported by: | Francesco Casella | Owned by: | Adeel Asghar |
---|---|---|---|
Priority: | blocker | Milestone: | 1.13.0 |
Component: | OMEdit | Version: | |
Keywords: | Cc: | Andrea Bartolini |
Description
Steps to reproduce the issue:
- open OMEdit 1.13.0-dev.beta1
- load the
ThermoPower.Test.WaterComponents.TestExpansionTankIdeal
model in OMEdit - run it
- select boiler.der(htilde[1])
An error window pops up, saying "Following variable(s) not found: boiler.der(htilde[1])".
This is fairly annoying, I would recommend if possible to fix it in 1.13.0.
Change History (3)
comment:1 by , 6 years ago
comment:2 by , 6 years ago
Resolution: | → fixed |
---|---|
Status: | new → closed |
Fixed in 4a8d97d/OMEdit and also pushed to 1.13 maintenance branch.
Note:
See TracTickets
for help on using tickets.
P.S. we just added that test model on GitHub today, you can't find it in the ThermoPower library shipped with 1.13.0-dev.beta1. Please fetch the library from https://github.com/casella/ThermoPower, HEAD revision.