Opened 9 years ago
Closed 7 years ago
#3865 closed defect (fixed)
OMEdit fails to import a 2.0 FMU that contains both ME and CS
Reported by: | Owned by: | Martin Sjölund | |
---|---|---|---|
Priority: | high | Milestone: | 1.13.0 |
Component: | FMI | Version: | v1.9.4-v1.9.x |
Keywords: | FMI, CS, ME | Cc: |
Description
The Error occurs with: OMEdit v1.9.5-dev-20-g6cc344e; Connected to OpenModelica v1.9.6 and the attached FMU exported from Dymola. According to the FMI specifictaion, it is allowed, that an FMU containes both ME and CS implementations.
There is an additional error regarding derivatives attributes, while the FMI compliance Checker reports not errors or warnings.
*
Error Messages:
[1] 19:47:51 Skripting Fehler
module = The derivative attribute may only appear on continuous-time Real variables., log level = ERROR: FMI2XML
[2] 19:47:51 Skripting Fehler
The FMU version is 2.0 and FMU type is ModelExchange and CoSimulation. Unsupported FMU type. Only FMI 2.0 ModelExchange is supported.
Attachments (1)
Change History (5)
by , 9 years ago
Attachment: | MODELICA_0Demo_testmotor_03.fmu added |
---|
comment:1 by , 9 years ago
The same error also occurs with FMUs generated from the same OMEdit version itself (with default settings.
comment:2 by , 7 years ago
Milestone: | Future → 1.13.0 |
---|---|
Owner: | changed from | to
Status: | new → accepted |
comment:4 by , 7 years ago
Resolution: | → fixed |
---|---|
Status: | accepted → closed |
FMU exorted from Dymola 2016FD01