Timeline
2020-02-26:
- 23:00 Ticket #5807 (Run-time - Start value for final parameters with fixed=false is ignored) updated by
- Yes, unfortunately @sjoelund.se's attempted fix to the problem of no …
- 22:38 Ticket #5814 (Code Generation - for loop in algorithm section gets wrong values) updated by
- @mahge930, you convinced me 100% that doing alias elimination of parts …
- 22:37 Ticket #5868 (Backend - Avoid alias elimination of individual elements of an array) updated by
-
Cc, Status, Owner changed
- 22:37 Ticket #5868 (Backend - Avoid alias elimination of individual elements of an array) created by
- Certain operations involving arrays (e.g. passing them as inputs to …
- 15:53 Ticket #5848 (OMSens - OMSens only detects topmost parameters of models) updated by
-
Priority changed
- 15:41 Ticket #5848 (OMSens - OMSens only detects topmost parameters of models) updated by
- Ticket will be split into two parts. One on the OMEdit side one on the …
- 15:41 Ticket #5848 (OMSens - OMSens only detects topmost parameters of models) updated by
-
Status, Owner changed
- 08:58 Ticket #5807 (Run-time - Start value for final parameters with fixed=false is ignored) updated by
- Replying to casella: > OK, thanks! Just started the …
- 08:08 Ticket #5867 (FMI - Implement fixed time step implicit Euler in FMI/CS) updated by
-
Description changed
2020-02-25:
- 15:31 Ticket #5814 (Code Generation - for loop in algorithm section gets wrong values) updated by
- Replying to casella: > I understand from our discussion …
- 14:20 Ticket #5867 (FMI - Implement fixed time step implicit Euler in FMI/CS) created by
- Currently, FMI/CS only provides explicit Euler. This is good for …
- 14:09 Ticket #5866 (New Instantiation - Update Save Total to NF) created by
- During today's devmeeting, I understood from @adrpo that the NF …
- 14:05 Ticket #5865 (Backend - Missing transformational debugger information for $cse implicit equations) created by
- Please run the attached test case with the OMEdit transformational …
- 13:54 Ticket #5679 (Run-time - +daeMode error with omc but not with OMEdit) updated by
-
P.S.
+daeMode
is obsolete, please use--daeMode
instead - 13:54 Ticket #5679 (Run-time - +daeMode error with omc but not with OMEdit) updated by
- Replying to anonymous: > Okay I got the same translation …
- 13:40 Ticket #5864 (Installation program - Bug during compilation, just after the installation) created by
- Hello, I have installed OpenModelica in order to evaluate the …
- 13:37 Ticket #5814 (Code Generation - for loop in algorithm section gets wrong values) updated by
-
Summary changed
- 13:36 Ticket #5814 (Code Generation - for loop in algorithm section gets wrong values) updated by
- I understand from our discussion during the devmeeting that the basic …
- 12:40 Ticket #5807 (Run-time - Start value for final parameters with fixed=false is ignored) updated by
- OK, thanks! Just started the …
- 10:16 Ticket #5807 (Run-time - Start value for final parameters with fixed=false is ignored) updated by
- It introduced some problems with the Chemical library. Hopefully fixed …
2020-02-24:
- 19:21 Ticket #3921 (Backend - Introduce wrapFunctionCalls and CSE also for the initial equations) updated by
- (Update) For the solution of this issue, we can safely assume that …
- 17:42 Ticket #5807 (Run-time - Start value for final parameters with fixed=false is ignored) updated by
- Excellent, I'm looking forward to this. BTW, we still have many …
- 17:40 Ticket #5795 (*unknown* - The backend does not compute strong components of initial equations ...) updated by
- The PR is merged, I just started a nightly build, I'll check that out …
- 14:47 Ticket #5807 (Run-time - Start value for final parameters with fixed=false is ignored) updated by
- The test is fixed. To shortly summarize what i did in pseudo code: …
- 14:28 Ticket #5795 (*unknown* - The backend does not compute strong components of initial equations ...) updated by
- Thanks that minimal model helped a lot! I realized that at some …
- 14:04 Ticket #5814 (Code Generation - for loop in algorithm section gets wrong values) updated by
- You can try simulating the model with the flags …
- 13:54 Ticket #5814 (Code Generation - for loop in algorithm section gets wrong values) updated by
- I guess this is the classic removeSimpleEquations alias issue. It …
- 12:37 Ticket #5863 (OMEdit - How to get the vector of values of a continuous variable) closed by
- invalid: This issue tracker is meant to provide feedback on issues with …
- 12:15 Ticket #5863 (OMEdit - How to get the vector of values of a continuous variable) updated by
- found or tried to write*
- 12:14 Ticket #5863 (OMEdit - How to get the vector of values of a continuous variable) created by
- Hello, I would like to get the vector of values corresponding to a …
- 12:09 Ticket #5862 (OMEdit - Make it possible to manage variable modifiers in OMEdit) updated by
-
Cc changed
- 12:08 Ticket #5862 (OMEdit - Make it possible to manage variable modifiers in OMEdit) created by
- One way to manage input variables in Modelica is through modifiers. …
2020-02-22:
- 14:39 Ticket #5797 (Backend - Disabling tearing breaks code generation in power system model when ...) updated by
-
The problem with
--tearingMethod=minimalTearing
has been fixed … - 13:57 Ticket #5861 (OMEdit - False while deleting library) closed by
- invalid
- 13:55 Ticket #5861 (OMEdit - False while deleting library) updated by
- Oh sorry, I reset my settings to solve the issue and now it's gone. …
- 13:50 Ticket #5861 (OMEdit - False while deleting library) updated by
-
Milestone changed
Can you provide the … - 13:41 Ticket #5861 (OMEdit - False while deleting library) created by
- Libraries cannot be unloaded. None of them. Returned following error: …
2020-02-21:
- 22:38 Ticket #5795 (*unknown* - The backend does not compute strong components of initial equations ...) updated by
- I just added a MWE that demonstrates the problem. The regular …
- 20:12 Ticket #5807 (Run-time - Start value for final parameters with fixed=false is ignored) updated by
- One test fails with an assertion at initialization: …
- 17:37 Ticket #5807 (Run-time - Start value for final parameters with fixed=false is ignored) updated by
- Possible fix in [https://github.com/OpenModelica/OpenModelica/pull/744 …
- 11:21 Ticket #5797 (Backend - Disabling tearing breaks code generation in power system model when ...) updated by
-
Owner changed
- 10:28 Ticket #3921 (Backend - Introduce wrapFunctionCalls and CSE also for the initial equations) updated by
- Solving this problem is not trivial, because many places in the …
- 01:48 Ticket #5843 (Run-time - Make sure daeMode works in a reliable way) updated by
- @Karim, can we please continue the discussion on #5860? Otherwise this …
2020-02-20:
- 22:51 Ticket #5843 (Run-time - Make sure daeMode works in a reliable way) updated by
- Replying to AnHeuermann: > Let's start with a first class …
- 21:56 Ticket #5859 (OMEdit - Make OMEdit display "pu" instead of "1"?) updated by
- See also #5773
- 21:55 Ticket #5859 (OMEdit - Make OMEdit display "pu" instead of "1"?) updated by
- Replying to dietmarw: > Well as EE I support this 1. :-) …
- 21:52 Ticket #5860 (Run-time - Provide correct and efficient event handling in --daeMode) updated by
-
Cc changed
- 21:51 Ticket #5860 (Run-time - Provide correct and efficient event handling in --daeMode) updated by
- As I understand it, the starting point is the synchronous data flow …
- 21:33 Ticket #5859 (OMEdit - Make OMEdit display "pu" instead of "1"?) updated by
- Replying to casella: > I support this 100%. Well as EE I …
- 21:25 Ticket #5843 (Run-time - Make sure daeMode works in a reliable way) updated by
- Replying to AnHeuermann: You correctly pointed out a …
- 21:24 Ticket #5860 (Run-time - Provide correct and efficient event handling in --daeMode) updated by
-
Status, Owner changed
- 21:24 Ticket #5860 (Run-time - Provide correct and efficient event handling in --daeMode) created by
- AnHeuermann reports in ticket:5843#comment:1: Let's start with a …
- 21:19 Ticket #5859 (OMEdit - Make OMEdit display "pu" instead of "1"?) updated by
- I support this 100%. BTW, we could have two different display units …
- 17:30 Ticket #5859 (OMEdit - Make OMEdit display "pu" instead of "1"?) created by
-
The unit for
Modelica.SIunits.PerUnit
is defined with "1" and also … - 14:18 Ticket #5843 (Run-time - Make sure daeMode works in a reliable way) updated by
- Let's start with a first class of problems: Verification failed …
- 10:38 Ticket #5726 (Third-Party Libraries - Categorize open-source libraries in OpenModelica for different uses) updated by
- For the record, I add the links to - the …
- 09:33 Ticket #5858 (Interactive Environment - Develop a manager for Modelica packages) updated by
-
Description changed
- 09:02 Ticket #5858 (Interactive Environment - Develop a manager for Modelica packages) updated by
-
Status, Owner, Description changed
- 08:57 Ticket #5858 (Interactive Environment - Develop a manager for Modelica packages) created by
- Backend: * We need to be able to categorize packages (#5726) - The …
2020-02-19:
- 21:55 Ticket #5726 (Third-Party Libraries - Categorize open-source libraries in OpenModelica for different uses) updated by
-
Description changed
- 21:48 Ticket #5857 (Backend - MSL OpAmp simulation results in OM) updated by
-
Priority, Owner, Component changed
- 21:41 Ticket #5857 (Backend - MSL OpAmp simulation results in OM) updated by
-
The OM strict simulation (
strict = true
) shows the following … - 21:30 Ticket #5857 (Backend - MSL OpAmp simulation results in OM) updated by
- Refs #5458
- 21:15 Ticket #5857 (Backend - MSL OpAmp simulation results in OM) created by
- I am referring to the recent PRs in the MSL 4.0.0 (and 3.2.3 …
- 19:34 Ticket #5726 (Third-Party Libraries - Categorize open-source libraries in OpenModelica for different uses) updated by
-
Description changed
- 18:03 Ticket #5297 (Interactive Environment - Support of conversion scripts) updated by
- Replying to perost: > I'm really not sure. Then we should …
- 17:58 Ticket #5854 (New Instantiation - NFConvertDAE.convertStateSelectAttribute got invalid StateSelect expression) updated by
- Thanks to the reporter and to the fixer! MWEs (in fact, MNWEs in …
- 16:33 Ticket #5847 (New Instantiation - Constant is used without having been given a value) updated by
-
FYI, I confirm (if there was any need for) that initializing
R_rel
… - 16:11 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
-
Cc, Status, Owner changed
- 16:11 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
- Seems to be an error with your model. You are initializing the …
- 14:13 Ticket #5797 (Backend - Disabling tearing breaks code generation in power system model when ...) updated by
- I'm adding the better error messages to PR …
- 14:10 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
- grid.mo was already attached at the first post
- 13:51 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
- With your model, it works. But i can´t set this flag in my grid model. …
- 13:42 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
- I wrote those lines in the fmu.mos and called it with the following …
- 13:20 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
- I don't have PyFMI installed, so I can't check what it's saying to …
- 13:19 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
- Minimal working example: […] I get a modelDescription.xml with […]
- 13:17 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
-
Status changed
I think this feature is right now available only with the cpp runtime. - 12:50 Ticket #5853 (FMI - -d=-disableDirectionalDerivatives Fails) updated by
-
Cc changed
- 11:51 Ticket #5854 (New Instantiation - NFConvertDAE.convertStateSelectAttribute got invalid StateSelect expression) closed by
- fixed: Fixed in d3c77b8.
- 11:04 Ticket #5854 (New Instantiation - NFConvertDAE.convertStateSelectAttribute got invalid StateSelect expression) updated by
- Replying to dariomangoni@…: > In the attachment you will …
- 10:59 Ticket #5856 (OMEdit - Use helper function instead of QString::number(double)) updated by
- https://github.com/OpenModelica/OpenModelica/pull/737 fixes the issue …
- 10:55 Ticket #5856 (OMEdit - Use helper function instead of QString::number(double)) created by
-
QString::number(double)
by default has a low precision, which might … - 10:22 Ticket #5297 (Interactive Environment - Support of conversion scripts) updated by
- Replying to casella: > The question is, is such a naive …
- 09:57 Ticket #5854 (New Instantiation - NFConvertDAE.convertStateSelectAttribute got invalid StateSelect expression) updated by
-
In the attachment you will find a
Test
model that should replicate … - 09:47 Ticket #5297 (Interactive Environment - Support of conversion scripts) updated by
- Replying to perost: > I'm not sure. A naive implementation …
- 08:58 Ticket #5297 (Interactive Environment - Support of conversion scripts) updated by
- Replying to casella: > How long do you think developing …
- 08:01 Ticket #5297 (Interactive Environment - Support of conversion scripts) updated by
- It was "ready next week" about 11 years ago, so I guess just a little …
Note:
See TracTimeline
for information about the timeline view.